污染(ran)源自動監測(ce)標氣配置相關要求
一、《固定(ding)污染(ran)源煙(yan)氣(qi)(qi)(qi)(qi)(SO2、NOX、顆粒物(wu))排放連續監測技術規范(HJ75-2017)》6.5監測站房(fang)內應配備不同(tong)濃(nong)(nong)度的(de)(de)有證標準(zhun)(zhun)(zhun)氣(qi)(qi)(qi)(qi)體,且在(zai)有效期內。標準(zhun)(zhun)(zhun)氣(qi)(qi)(qi)(qi)體應當(dang)包含(han)(han)零氣(qi)(qi)(qi)(qi)(即含(han)(han)二(er)氧(yang)化硫、氮氧(yang)化物(wu)濃(nong)(nong)度均(jun)≤0.1μmol/mol的(de)(de)標準(zhun)(zhun)(zhun)氣(qi)(qi)(qi)(qi)體,一般為高純(chun)氮氣(qi)(qi)(qi)(qi),純(chun)度≥99.999%;當(dang)測量煙(yan)氣(qi)(qi)(qi)(qi)中(zhong)(zhong)二(er)氧(yang)化碳時,零氣(qi)(qi)(qi)(qi)中(zhong)(zhong)二(er)氧(yang)化碳≤400μmol/mol,含(han)(han)有其(qi)他(ta)氣(qi)(qi)(qi)(qi)體的(de)(de)濃(nong)(nong)度不得干(gan)擾儀(yi)器的(de)(de)讀數)和CEMS測量的(de)(de)各(ge)種氣(qi)(qi)(qi)(qi)體(SO2、NOx、O2)的(de)(de)量程標氣(qi)(qi)(qi)(qi),以滿足日常零點、量程校準(zhun)(zhun)(zhun)、校驗的(de)(de)需(xu)要(yao)。低濃(nong)(nong)度標準(zhun)(zhun)(zhun)氣(qi)(qi)(qi)(qi)體可由高濃(nong)(nong)度標準(zhun)(zhun)(zhun)氣(qi)(qi)(qi)(qi)體通過經校準(zhun)(zhun)(zhun)合格(ge)的(de)(de)等比(bi)例稀釋(shi)設備獲(huo)得(精(jing)密(mi)度≤1%)%),也可單獨配備。
關注點:
1.監測(ce)站房內應配備不同濃度的(de)有證標準氣體,且在有效期內。
2.監測站房配(pei)備標(biao)(biao)(biao)氣(qi)包括零氣(qi)、SO2量(liang)程(cheng)標(biao)(biao)(biao)氣(qi)、NOx量(liang)程(cheng)標(biao)(biao)(biao)氣(qi)、O2量(liang)程(cheng)標(biao)(biao)(biao)氣(qi)。
3.低濃度標準(zhun)氣(qi)體可由高(gao)濃度標準(zhun)氣(qi)體通(tong)過經校準(zhun)合格的等比(bi)例稀釋設備獲得(精密度≤1%)%),也可單獨配備。
現場采樣(yang)
二、《固定(ding)污染源煙氣(qi)(SO2、NOX、顆粒物(wu))排放連續監測(ce)技術規范(HJ75-2017)》9.3.1.5現場驗收時必須(xu)采用有證標(biao)(biao)準(zhun)(zhun)(zhun)物(wu)質或(huo)標(biao)(biao)準(zhun)(zhun)(zhun)樣品,較低(di)濃(nong)度的(de)標(biao)(biao)準(zhun)(zhun)(zhun)氣(qi)體可以(yi)使用高(gao)濃(nong)度的(de)標(biao)(biao)準(zhun)(zhun)(zhun)氣(qi)體采用等比(bi)(bi)例稀釋(shi)方法獲得,等比(bi)(bi)例稀釋(shi)裝置(zhi)的(de)精密度在1%以(yi)內。標(biao)(biao)準(zhun)(zhun)(zhun)氣(qi)體要求貯存(cun)在鋁或(huo)不銹鋼瓶中,不確定(ding)度不超(chao)過±2%。
關注點:
1.現場驗收(shou)時必須采用有證(zheng)標準物(wu)質或標準樣品。
2.較低濃度(du)(du)的標準氣體(ti)可以使(shi)用高濃度(du)(du)的標準氣體(ti)采用等比例(li)稀(xi)釋方(fang)法獲得,等比例(li)稀(xi)釋裝置(zhi)的精(jing)密(mi)度(du)(du)在1%以內。
3.標準氣(qi)體(ti)要(yao)求貯存在鋁或不銹(xiu)鋼瓶中,不確定度不超過(guo)±2%。
示值誤差(cha)
三、《固定污染源(yuan)煙氣(SO2、NOX、顆(ke)粒物)排放連續監測技(ji)術規范(HJ75-2017)》9.3.3.2a)示(shi)值誤差:
1)通入零氣(qi)(qi)(經(jing)過濾(lv)的不含顆粒物、待測氣(qi)(qi)體(ti)的清潔干空氣(qi)(qi)或高純氮氣(qi)(qi)),調節(jie)儀器(qi)零點。
2)通入高濃(nong)度(du)(80%~100%的滿量程(cheng)值(zhi))標準氣(qi)體,調(diao)整儀(yi)器顯示濃(nong)度(du)值(zhi)與標準氣(qi)體濃(nong)度(du)值(zhi)一致(zhi)。
3)儀(yi)器經上述(shu)校準(zhun)后,按(an)(an)照零(ling)(ling)氣(qi)、高(gao)(gao)濃(nong)(nong)(nong)(nong)度(du)(du)標(biao)準(zhun)氣(qi)體(ti)、零(ling)(ling)氣(qi)、中濃(nong)(nong)(nong)(nong)度(du)(du)(50%~60%的滿(man)量程(cheng)值(zhi))標(biao)準(zhun)氣(qi)體(ti)、零(ling)(ling)氣(qi)、低(di)濃(nong)(nong)(nong)(nong)度(du)(du)(20%~30%的滿(man)量程(cheng)值(zhi))標(biao)準(zhun)氣(qi)體(ti)的順序通入標(biao)準(zhun)氣(qi)體(ti)。若低(di)濃(nong)(nong)(nong)(nong)度(du)(du)標(biao)準(zhun)氣(qi)體(ti)濃(nong)(nong)(nong)(nong)度(du)(du)高(gao)(gao)于排(pai)放(fang)限值(zhi),則還需通入濃(nong)(nong)(nong)(nong)度(du)(du)低(di)于排(pai)放(fang)限值(zhi)的標(biao)準(zhun)氣(qi)體(ti),完成(cheng)超(chao)低(di)排(pai)放(fang)改造后的火電污染源還應通入濃(nong)(nong)(nong)(nong)度(du)(du)低(di)于超(chao)低(di)排(pai)放(fang)水(shui)平(ping)的標(biao)準(zhun)氣(qi)體(ti)。待顯示(shi)濃(nong)(nong)(nong)(nong)度(du)(du)值(zhi)穩定(ding)后讀取測定(ding)結果(guo)。重復測定(ding)3次(ci),取平(ping)均值(zhi)。按(an)(an)附(fu)錄(lu)A公式(A19)、(A20)計算示(shi)值(zhi)誤差(cha)。
關注點:
1.氣(qi)(qi)態(tai)污染物和氧氣(qi)(qi)示(shi)(shi)值(zhi)(zhi)誤差驗收流程(cheng):先通(tong)入零(ling)氣(qi)(qi)調節儀器零(ling)點,載通(tong)入高濃度(du)(du)(80%~100%的滿(man)量程(cheng)值(zhi)(zhi))標(biao)(biao)(biao)(biao)(biao)準氣(qi)(qi)體(ti)(ti),調整儀器顯示(shi)(shi)濃度(du)(du)值(zhi)(zhi)與標(biao)(biao)(biao)(biao)(biao)準氣(qi)(qi)體(ti)(ti)濃度(du)(du)值(zhi)(zhi)一致,再按(an)照零(ling)氣(qi)(qi)、高濃度(du)(du)標(biao)(biao)(biao)(biao)(biao)準氣(qi)(qi)體(ti)(ti)、零(ling)氣(qi)(qi)、中(zhong)濃度(du)(du)(50%~60%的滿(man)量程(cheng)值(zhi)(zhi))標(biao)(biao)(biao)(biao)(biao)準氣(qi)(qi)體(ti)(ti)、零(ling)氣(qi)(qi)、低濃度(du)(du)(20%~30%的滿(man)量程(cheng)值(zhi)(zhi))標(biao)(biao)(biao)(biao)(biao)準氣(qi)(qi)體(ti)(ti)的順序通(tong)入標(biao)(biao)(biao)(biao)(biao)準氣(qi)(qi)體(ti)(ti),分別讀取測定結(jie)果(guo),做3次,取平均值(zhi)(zhi)。
2.氣(qi)(qi)態污染物和氧氣(qi)(qi)示值誤差(cha)驗收所(suo)需(xu)標(biao)氣(qi)(qi):零氣(qi)(qi)、高濃度(du)(du)標(biao)準氣(qi)(qi)體(ti)、中(zhong)濃度(du)(du)(50%~60%的滿(man)量(liang)(liang)程(cheng)(cheng)值)標(biao)準氣(qi)(qi)體(ti)、低(di)濃度(du)(du)(20%~30%的滿(man)量(liang)(liang)程(cheng)(cheng)值)。
調試檢測方法(fa)
四、《固(gu)定(ding)污染源(yuan)煙氣(qi)(SO2、NOX、顆(ke)粒物)排放連續監測(ce)技術規(gui)范(HJ75-2017)》A.4.1氣(qi)態污染物CEMS和氧氣(qi)CMS示值誤差調試檢測(ce)方法:
a)儀器通入零氣,調節儀器零點。
b)通入(ru)高濃度(80%~100%的滿量(liang)程(cheng)值(zhi))標準(zhun)(zhun)氣體(ti),調整儀(yi)器顯示(shi)濃度值(zhi)與標準(zhun)(zhun)氣體(ti)濃度值(zhi)一致。
c)儀(yi)器經上述(shu)校準(zhun)(zhun)(zhun)(zhun)后(hou),按(an)照(zhao)零(ling)氣(qi)(qi)(qi)、高濃(nong)(nong)度(du)標(biao)(biao)(biao)準(zhun)(zhun)(zhun)(zhun)氣(qi)(qi)(qi)體、零(ling)氣(qi)(qi)(qi)、中濃(nong)(nong)度(du)(50%~60%的(de)(de)滿(man)(man)量程(cheng)值(zhi)(zhi))標(biao)(biao)(biao)準(zhun)(zhun)(zhun)(zhun)氣(qi)(qi)(qi)體、零(ling)氣(qi)(qi)(qi)、低(di)濃(nong)(nong)度(du)(20%~30%的(de)(de)滿(man)(man)量程(cheng)值(zhi)(zhi))標(biao)(biao)(biao)準(zhun)(zhun)(zhun)(zhun)氣(qi)(qi)(qi)體的(de)(de)順序通入(ru)標(biao)(biao)(biao)準(zhun)(zhun)(zhun)(zhun)氣(qi)(qi)(qi)體。若(ruo)低(di)濃(nong)(nong)度(du)標(biao)(biao)(biao)準(zhun)(zhun)(zhun)(zhun)氣(qi)(qi)(qi)體濃(nong)(nong)度(du)高于(yu)排(pai)放(fang)限(xian)值(zhi)(zhi),則還(huan)需(xu)通入(ru)濃(nong)(nong)度(du)低(di)于(yu)排(pai)放(fang)限(xian)值(zhi)(zhi)的(de)(de)標(biao)(biao)(biao)準(zhun)(zhun)(zhun)(zhun)氣(qi)(qi)(qi)體,完成超低(di)排(pai)放(fang)改造(zao)后(hou)的(de)(de)火電污染源還(huan)應通入(ru)濃(nong)(nong)度(du)低(di)于(yu)超低(di)排(pai)放(fang)水平(ping)的(de)(de)標(biao)(biao)(biao)準(zhun)(zhun)(zhun)(zhun)氣(qi)(qi)(qi)體。待顯示濃(nong)(nong)度(du)值(zhi)(zhi)穩定后(hou)讀取測定結果。重復測定3次,取平(ping)均值(zhi)(zhi)。按(an)附(fu)錄A公式(A19)、(A20)計算示值(zhi)(zhi)誤差。
關注(zhu)點(dian):
氣態污(wu)染(ran)物CEMS和氧(yang)氣CMS示值(zhi)誤差調(diao)試檢測(ce)方法與驗收方法一致,均需要調(diao)節零點、量程,并(bing)通(tong)入(ru)高、中、低標(biao)準氣體讀取測(ce)定結果,重復測(ce)定3次,取平均值(zhi)。
校準和校驗操作規程
五、《固定污染源煙氣(SO2、NOX、顆粒物(wu))排(pai)放連續監(jian)測(ce)技(ji)術(shu)規(gui)范(HJ75-2017)》10.4CEMS的(de)校(xiao)準和(he)校(xiao)驗,應根據本標準中規(gui)定的(de)方法和(he)第11章質量保證(zheng)規(gui)定的(de)周(zhou)期(qi)制訂CEMS系統(tong)的(de)日常校(xiao)準和(he)校(xiao)驗操作規(gui)程。校(xiao)準和(he)校(xiao)驗記(ji)錄應及時歸檔。
關注點(dian):
CEMS的(de)(de)校(xiao)(xiao)(xiao)準(zhun)和(he)校(xiao)(xiao)(xiao)驗根據(HJ75-2017)規(gui)定的(de)(de)方法制訂CEMS系(xi)統(tong)的(de)(de)日(ri)常校(xiao)(xiao)(xiao)準(zhun)和(he)校(xiao)(xiao)(xiao)驗操作規(gui)程。
CEMS的校準和校驗(yan)根據(HJ75-2017)第(di)11章質量保證規(gui)定的周(zhou)期執行。
定期校(xiao)準要(yao)求
六(liu)、《固定污染源煙氣(qi)(qi)(SO2、NOX、顆粒物)排放連(lian)續(xu)監測(ce)技術規范(HJ75-2017)》11.2定期校準(zhun)(zhun)要求,抽取式氣(qi)(qi)態污染物CEMS每3個(ge)月至(zhi)少進行一次全系統(tong)的校準(zhun)(zhun),要求零氣(qi)(qi)和標準(zhun)(zhun)氣(qi)(qi)體(ti)從監測(ce)站房發(fa)出(chu),經采樣探頭末端與(yu)樣品氣(qi)(qi)體(ti)通過(guo)的路徑(應包括采樣管路、過(guo)濾(lv)器(qi)(qi)、洗滌器(qi)(qi)、調節器(qi)(qi)、分析儀表等(deng))一致(zhi),進行零點(dian)和量程漂移、示值誤差和系統(tong)響(xiang)應時間的檢測(ce)。
關注點:
1.抽取(qu)式(shi)氣態污(wu)染物CEMS每3個月至(zhi)少進行一次(ci)全(quan)系統(tong)的校準,檢(jian)測(ce)內容包括示值誤差檢(jian)測(ce)。
要求(qiu)及檢測方法
七、《固定污染源煙氣(SO2、NOX、顆(ke)粒物)排放連(lian)續監測(ce)系統技術(shu)要求(qiu)及檢(jian)測(ce)方法(HJ76-2017)》7.1.2.2標(biao)準(zhun)(zhun)氣體(ti)(ti):由國家(jia)計量主管(guan)部門(men)批準(zhun)(zhun)的(de)國家(jia)一(yi)、二級標(biao)準(zhun)(zhun)氣體(ti)(ti),其不確(que)定度(du)(du)(du)不超過±2.0%。量程校(xiao)準(zhun)(zhun)氣體(ti)(ti)指濃度(du)(du)(du)在(zai)(80%~100%)滿(man)量程范圍(wei)內的(de)標(biao)準(zhun)(zhun)氣體(ti)(ti)。較低(di)濃度(du)(du)(du)的(de)標(biao)準(zhun)(zhun)氣體(ti)(ti)如不能(neng)滿(man)足(zu)不確(que)定度(du)(du)(du)要求(qiu),可以使用(yong)滿(man)足(zu)要求(qiu)的(de)高濃度(du)(du)(du)標(biao)準(zhun)(zhun)氣體(ti)(ti)采用(yong)等(deng)比例稀釋的(de)方式獲(huo)得(de),等(deng)比例稀釋裝置的(de)精密度(du)(du)(du)應(ying)在(zai)1.0%以內。
關注點:
標準(zhun)氣體(ti)(ti):由國(guo)家(jia)計量主管部門批準(zhun)的國(guo)家(jia)一、二級(ji)標準(zhun)氣體(ti)(ti),其不確定(ding)度不超過(guo)±2.0%。
量程(cheng)校準氣體(ti)指濃度在(80%~100%)滿(man)量程(cheng)范圍內的(de)標準氣體(ti)。
較低濃(nong)度(du)的(de)標(biao)準氣體可以(yi)使用(yong)高濃(nong)度(du)標(biao)準氣體采(cai)用(yong)等比例稀釋的(de)方式獲得,等比例稀釋裝置的(de)精(jing)密度(du)應在1.0%以(yi)內。
綜上,一個(ge)涉及SO2、NOX、顆(ke)粒物(wu)的(de)(de)分(fen)析(xi)小屋需(xu)(xu)配(pei)置零氣和CEMS測量(liang)(liang)(liang)(liang)的(de)(de)各種氣體(ti)(ti)(ti)(SO2、NOx、O2)的(de)(de)量(liang)(liang)(liang)(liang)程(cheng)標(biao)(biao)氣,以(yi)(yi)滿足日常(chang)零點(dian)、量(liang)(liang)(liang)(liang)程(cheng)校準(zhun)、校驗的(de)(de)需(xu)(xu)要。抽(chou)取式氣態(tai)污染物(wu)CEMS每3個(ge)月(yue)至少進行一次全系統的(de)(de)校準(zhun),做示值誤差時需(xu)(xu)按照零氣、高(gao)濃(nong)度(80%~100%的(de)(de)滿量(liang)(liang)(liang)(liang)程(cheng)值)標(biao)(biao)準(zhun)氣體(ti)(ti)(ti)、零氣、中濃(nong)度(50%~60%的(de)(de)滿量(liang)(liang)(liang)(liang)程(cheng)值)標(biao)(biao)準(zhun)氣體(ti)(ti)(ti)、零氣、低濃(nong)度(20%~30%的(de)(de)滿量(liang)(liang)(liang)(liang)程(cheng)值)標(biao)(biao)準(zhun)氣體(ti)(ti)(ti)的(de)(de)順序通入標(biao)(biao)準(zhun)氣體(ti)(ti)(ti)。所以(yi)(yi)一個(ge)涉及SO2、NOX、顆(ke)粒物(wu)的(de)(de)分(fen)析(xi)小屋至少需(xu)(xu)要配(pei)備零氣和SO2、NOx、O2三種氣體(ti)(ti)(ti)對應高(gao)中低三種濃(nong)度的(de)(de)標(biao)(biao)氣共計10瓶(ping)標(biao)(biao)準(zhun)氣體(ti)(ti)(ti),零氣和量(liang)(liang)(liang)(liang)程(cheng)標(biao)(biao)氣使用頻率較高(gao),可(ke)以(yi)(yi)多配(pei)。